CoatStarOpen workspace

CoatStar user guide

From a coating requirement to a reviewable design, spectrum, and tolerance analysis.

Shared public account: everyone using public shares the same tasks, designs, and files. Other visitors can see or change them. Use synthetic or sanitized data only; do not upload private, customer, or confidential information.

Getting started

  1. Open the English workspace. Use the public credentials displayed on the login page, or sign in to your own account.
  2. The left pane lists tasks; the center contains the specification and conversation; the right pane contains results and files. On narrow screens, scroll down to move between sections.
  3. To see a read-only overview without logging in, open the Featured Demo. It is a precomputed example, not a live calculation.

Review the saved BBAR example

  1. Sign in to the shared public account and select Featured BBAR Demo · BK7 · 450–650 nm. The task ID is 55209c754d0644cc93b12b50479a3084.
  2. Review the confirmed v1 specification, four-layer stack, three-angle performance, spectrum, manufacturing checks, and tolerance simulation in the task and results panes.
  3. Use Download engineering report ZIP for the complete package; the tolerance report ZIP and its CSV files are listed among the task artifacts.
Example result: 450–650 nm on BK7 at 0°, 15°, and 30°, sampled every 5 nm. The maximum reflectance is 0.4882%, 0.4511%, and 0.5460%; all are below the 1.0% maximum target, while the per-angle average remains below 0.5%. A 100-sample normal thickness-error simulation (σ = 1%, truncated at ±3%; seed 20261010) estimated a 100% joint pass rate with a 95% interval of 96.30%–100%. This is not factory yield. Engineer approval remains pending.

The public workspace is shared, so its contents may be changed by another visitor. The Featured BBAR Demo is a historical synthetic engineering record, not a live calculation.

Create a design

  1. Select New task using the plus button in the task pane. Enter a requirement in the message box and select Send, or choose Visible BBAR to insert an example request.
  2. Include the substrate, wavelength range and sampling step, incidence medium, angles, polarization, coated surface, and whether the back surface is evaluated. State performance limits, permitted materials, layer-count and thickness limits, and the compute budget.
  3. Review the structured specification. Check the units, all angles, R_avg and R_max limits, material list, and any missing or conflicting fields. For a limit at every sampled wavelength, specify a peak target such as R_max < 0.5%; an average alone does not guarantee that limit.
  4. To correct a field, send a clear supplemental instruction and review the updated specification. Saving a draft does not start computation. A seed can be selected explicitly before confirmation if one is appropriate.
  5. Only when the displayed specification is correct, select Confirm specification and start design. Wait for the background job to finish. The visible multi-angle workflow uses a bounded search; a failed search is not proof that the design is physically impossible.

Manual specification entry and drawing intake availability depend on the account and deployment. The shared public account uses the text-based demonstration path. Do not assume a drawing has been interpreted correctly without reviewing every extracted field.

Review the design

Run tolerance analysis

  1. Open a task with a valid nominal design. Ask for a tolerance draft for that design, or use the Tolerance analysis shortcut where available.
  2. State the error model: layer-thickness distribution and amplitude, any truncation, systematic bias, refractive-index and angle errors, correlations, sample count, random seed, and time budget. Distinguish a normal standard deviation from a plus/minus bound.
  3. Check the displayed draft and explicitly confirm it. The analysis uses the selected nominal design; it does not require a new optimization.
  4. Read the joint simulated pass rate, 95% confidence interval, completed and invalid samples, and signed sensitivity results. These depend on the declared model and are not measured manufacturing yield. Unsupported error models and equipment effects remain unevaluated.

Download and share results

The engineering ZIP contains the specification, layer table, spectrum data, optical compliance, version information, and approval status. The tolerance ZIP contains its assumptions, report, sample CSV, and sensitivity CSV. Check that the task, specification version, design run, and tolerance run match before sharing.

Troubleshooting